Cooling tower media

Cooling tower media

Wide-Format Rigid Fill Media for Customized Cooling Tower Applications

Wide-Format Rigid Fill Media for Customized Cooling Tower Applications

Contact: Sam
Address: Guangdong, China
Click:

Product Overview

Wide-Format Rigid Fill Media for Customized Cooling Tower Applications

Our Rigid Fill Media is available in a wide selection of widths for cooling tower projects that require defined fill dimensions and a consistent corrugated structure. With a 15mm pitch, 5.5° angle, and customizable length and thickness, the product provides a flexible format for different fill media configurations.

Wide Rigid Fill Media Dimensions

The available widths are 1220mm, 1320mm, 1520mm, 1600mm, 1620mm, 1700mm, and 1800mm. This range provides several options for projects using wider fill sections and allows the fill media dimensions to be selected according to the intended arrangement.

While the width is available in multiple specifications, both length and thickness can be customized. This makes it possible to establish the finished media dimensions around the requirements of a particular cooling tower project.

Defined 15mm Pitch Structure

The fill media features a 15mm pitch and a 5.5° angle. The corrugated configuration creates the repeated structure of the fill sheets and provides a clearly defined specification for customers selecting rigid film-type media.

This fixed pitch and angle can be combined with different widths and customized dimensions, giving customers a consistent product structure while allowing flexibility in the overall size.

Material Options

Although this product is offered as a rigid fill media solution, material selection is not limited to one plastic type. Available materials include PVC, CPVC, and PP.

This gives customers the flexibility to specify the material together with the required dimensions and operating requirements rather than choosing a fixed material configuration.

Glue or Hang Connection

The available connection methods are glue or hang. Depending on the fill pack design, either method can be selected for assembling the sheets into the required media configuration.

The two connection options also make the product adaptable to different project arrangements, including applications where replacement media needs to follow an existing assembly method.

Rigid Fill Media for Customized Projects

Standard dimensions are not always sufficient for cooling tower replacement or new-build requirements. With seven width options and customizable length and thickness, this fill media provides a broader specification range for projects where the final fill dimensions need to be established individually.

Customers can provide their required fill dimensions, material preference, and connection method when requesting the product, allowing the media configuration to be prepared around the actual project specification.

Product Specifications

Connection MethodGlue or Hang
Width1220mm, 1320mm, 1520mm, 1600mm, 1620mm, 1700mm, 1800mm
LengthCustomized
ThicknessCustomized
Pitch15mm
MaterialPVC, CPVC, PP
Angle5.5°

Custom Rigid Fill Media for Cooling Towers

Combining a defined 15mm pitch and 5.5° angle with wide width options, customized length and thickness, and PVC, CPVC, or PP material choices, this Rigid Fill Media provides a flexible product specification for cooling tower projects. The glue or hang connection options allow the final fill pack to be configured according to the required assembly method.

User avatar
Ahmed Hassan
Procurement Manager
The fill materials arrived in good condition, and their team handled our technical requirements carefully.
User avatar
Minho Park
Industrial Cooling Specialist
We have cooperated with them on several cooling tower maintenance projects. Their corrugated cooling tower fill has shown good performance and stable structural performance.
User avatar
Carlos Martinez
Carlos-Martinez
They supplied high-quality PVC film fill for our HVAC project. The products were carefully packed and delivered on schedule
User avatar
Oliver Bennett
Cooling Tower Design Engineer
Reliable cooling tower fill manufacturer with professional technical support.
Can you assist with cooling tower fill installation planning and selection?
We provide technical suggestions for cooling tower fill installation methods, product matching, and system conditions. Project details can be discussed according to tower design, operating environment
What Is The Production Time For Your Cooling Tower Fill Media?
We offer technical advice on cooling tower fill installation, product matching and system conditions. Project details can be discussed based on tower design, operating environment and client requireme
Is your cooling tower fill suitable for fire‑safety‑oriented cooling projects?
Our PVC cooling tower fill ensures stable performance across various cooling environments. Suitable solutions can be offered based on tower structure and operating‑site requirements.
What cooling applications are suitable for your cooling tower fill media?
Our cooling tower fill media suits industrial cooling systems for efficient heat transfer. Custom options are available based on tower structure, water conditions and project needs.
Contact Us for More Information
Rigid Cooling Tower Fill with Flexible Width and Installation Options Rigid PVC Fill for Clearly Specified Cooling Tower Projects
Technical Resources

Cooling Tower Fill Information

News, product guides, and practical references from our cooling tower fill media specialists.

CHUANGMENG PLASTIC COMPANY
16+Years of Trust
Company Profile

CHUANGMENG PLASTIC COMPANY

We develops and manufactures cooling tower fill products, supporting different cooling system applications with practical engineering solutions and production capabilities.

  • Years of experience in cooling tower fill production
  • Controlled manufacturing and product inspection procedures
  • Flexible sizing and customization options
  • Project communication and after-sales technical support
More About Us
Start A Discussion

Cooling Tower Fill Solutions

Provide your project details for suitable cooling tower fill options and technical communication.

Chat with us on WhatsApp